L-314
Modified Epoxy Film Adhesive, High Toughness |
|
|
| Mechanical Properties: 0.060 lbs/ft2 (292 g/m2) Adhesive Film |
Property |
25 PSI (0.17 MPa) Cure in Platen Press |
Press Cure after 1 Month Outlife |
Test Method |
|
|
|
|
Tensile Shear Strength |
|
|
|
-67°F (-55°C) |
6,700 PSI (46.2 MPa) |
6,680 PSI (46.0 MPa) |
ASTM D1002 |
Room Temp |
5,900 PSI (40.6 MPa) |
5,950 PSI (41.0 MPa) |
ASTM D1002 |
180°F (82°C) |
4,600 PSI (31.6 MPa) |
4,500 PSI (31.0 MPa) |
ASTM D1002 |
250°F (121°C) |
2,250 PSI (15.5 MPa) |
2,000 PSI (13.8 MPa) |
ASTM D1002 |
|
|
|
|
Sandwich Peel Strength |
|
|
|
-67°F (-55°C) |
42 in lb/in (187 Nm/m) |
40 in lb/in (178 Nm/m) |
ASTM D1781 |
Room Temp |
39 in lb/in (173 Nm/m) |
35 in lb/in (156 Nm/m) |
ASTM D1781 |
180°F (82°C) |
35 in lb/in (156 Nm/m) |
32 in lb/in (142 Nm/m) |
ASTM D1781 |
|
|
|
|
Flatwise Tensile Strength |
|
|
|
-67°F (-55°C) |
1,250 PSI (8.6 MPa) |
1,140 PSI (7.9 MPa) |
ASTM C297 |
Room Temp |
1,120 PSI (7.7 MPa) |
1,100 PSI (7.6 MPa) |
ASTM C297 |
180°F (82°C) |
660 PSI (4.5 MPa) |
620 PSI (4.3 MPa) |
ASTM C297 |
|
|
|
|
Sandwich Flexural Strength |
|
|
|
-67°F (-55°C) |
core failure |
core failure |
ASTM C393 |
Room Temp |
core failure |
core failure |
ASTM C393 |
180°F (82°C) |
core failure |
core failure |
ASTM C393 |
|
|
|
|
T-Peel Strength |
|
|
|
-67°F (-55°C) |
52 in lb/in (231 N/25 mm) |
50 in lb/in (223 N/25 mm) |
ASTM D1876 |
Room Temp |
49 in lb/in (218 N/25 mm) |
47 in lb/in (209 N/25 mm) |
ASTM D1876 |
180°F (82°C) |
41 in lb/in (182 N/25 mm) |
40 in lb/in (178 N/25 mm) |
ASTM D1876 |
|
|
|
|
Floating Roller Peel Strength |
|
|
|
-67°F (-55°C) |
105 in lb/in (467 N/25mm) |
104 in lb/in (463 N/25 mm) |
ASTM D3167 |
Room Temp |
95 in lb/in (423 N/25 mm) |
94 in lb/in (418 N/25 mm) |
ASTM D3167 |
180°F (82°C) |
85 in lb/in (378 N/25 mm) |
82 in lb/in (365 N/25 mm) |
ASTM D3167 |
|
|
|
|
NOTICE:Product data and parameters cited in this publication have been obtained in J.D. Lincoln, Inc. laboratories using the materials under carefully controlled conditions. The information, therefore, is believed to be accurate and correctly stated. Data of this type may be considered to be indicative of representative properties obtainable. J.D. Lincoln, Inc. cannot accept responsibility for the misapplication of these products, nor for their use under uncontrolled conditions. Numerical values resulting from the application of this material are dependant on processing details. It is recommended that the user develop his or her own application techniques and generate data consistent with his or her specific application and process.
|
|
|